OPAC100 SPECIFICATIONS
Operational:
Light source: red light
emitting diode Accuracy: +/- 3 % opacity Response time: < 3 seconds Angle of projection: less than 5 degrees Angle of view: less than 5 degrees Resolution: 0.1 % opacity Path length correction factor (PLCF): adjustable Outputs: One linear 4-20 ma analog output. Two spdt alarm contact relays, opacity warning, opacity alarm. Values user adjustable.
Environmental: Ambient temperature: - 40 to +130 F Media temperature: maximum 2000 F Pressure: - 10 up to + 10 inches H2O Pathlength: 2 to 30 feet Moisture: dry to saturated ( non condensing)
Electrical requirements: Purge blowers: 115vac /15 amps (220v / 50hz available) Electronic control unit: 115 vac / 2 amps (220v / 50 hz available) Source to electronic unit wiring: 20 feet included Detector to electronic unit wiring: 20 feet included (Consult factory for longer wiring lengths) Physical: Transmissometer side 9 ½ inches long 3 inches diameter. Detector side 9 ½ inches long 3 inches diameter.
Remote Electronics unit: Height:10 inches Width: 10 inches Depth: 4 inches © Phoenix instruments Inc. 1999 |